§ 10-4-6. STREET DRAINAGE; FLOW.  


Latest version.
  • (A) For street flow, the street drainage criteria of Section 3 of the Drainage Design Manual for Maricopa County, Volume II, Hydraulics shall apply except as amended herein. The Rational Method shall be used to calculate street runoff as stated in Apache Junction City Code Vol. II, § 10-4-5(B) of these standards.
    (B) Calculations shall be submitted which indicate compliance with the criteria as stated in Apache Junction City Code Vol. II, § 10-4-2(B) of these standards.
    (C) A 7-inch curb may be allowed to increase the street capacity and eliminate the need for storm drains and may only be used for short sections of streets near drain inlets with the approval of the city engineer.
    (Ord. passed - - )